Know a company with years of records? Refer it and earn up to $100K
Pathology resource

Digital Pathology: Whole Slide Imaging and Slide Retention

What digital pathology and whole slide imaging are, how slides are scanned and stored, FDA, CAP and CMS rules, and how long CLIA says to keep slides.

Short answerChecked

Digital pathology means scanning glass pathology slides into high-resolution whole slide images, then viewing, sharing, storing and analyzing them on screen. A slide scanner captures the tissue in tiles, usually at 20x or 40x. The FDA has authorized whole slide imaging systems for primary diagnosis since 2017, but labs still keep the glass: CLIA requires histopathology slides for at least 10 years.

Histopathology slides under CLIA
10 years42 CFR 493.1105
Paraffin blocks under CLIA
2 years minimum
First whole slide imaging system authorized
2017FDA de novo pathway
A dispatch clipboard and barcode scanner in a warehouse office
Key points
  • A whole slide image is a tiled, multi-resolution copy of one glass slide, and a single slide can exceed several gigabytes.
  • The FDA regulates whole slide imaging systems as Class II devices, and the CAP guideline asks labs to validate them against light microscopy first.
  • CLIA sets minimums: histopathology slides 10 years, cytology slides 5 years, blocks 2 years, pathology reports 10 years.
  • Most scanners save in their own file format. DICOM has covered whole slide images since 2010 and makes them easier to move.

What is digital pathology?

Digital pathology is pathology practiced from scanned images of glass slides. The FDA defines it this way: "Digital pathology is the development of digital scans of pathology tissues from slides and the visualization, analysis, transfer, storage, and interpretation of the resulting data" (FDA). The Digital Pathology Association, quoted in a 2026 review, calls it "a dynamic, image-based environment that enables the acquisition, management, and interpretation of pathology information generated from a digitized glass slide" (Journal of Pathology Informatics). Digital histopathology means the same thing for tissue slides.

The glass still comes first. For over a century, "tissue specimens were fixed, sectioned, mounted on glass slides, and examined using a conventional light microscope" (Journal of Pathology Informatics), and the FDA describes the same step: "In pathology, biopsied tissues are mounted onto glass slides and stained for viewing and evaluation" (FDA). Those stained histopathological slides are what a scanner digitizes. "The routine H&E slides as well as special stains, immunochemistry, or fluorescent-labeled slides can be digitally archived" (Journal of Digital Imaging), but scanning adds a step rather than removing one: "WSI in pathology does not reduce the laboratory's workload since glass slides still need to be prepared to be scanned."

Labs that will not ship slide images can still join federated research, which trains inside the custodian's systems and combines only model weights; the Apheris trust check covers one network, built for drug discovery.

What is whole slide imaging?

Whole slide imaging (WSI) turns an entire glass slide into one navigable image. In the FDA's rule, "The whole slide imaging system is an automated digital slide creation, viewing, and management system intended as an aid to the pathologist to review and interpret digital images of surgical pathology slides" (21 CFR 864.3700).

A digital pathology scanner does the capture. "Image capture is performed by a digital scanner, which is basically a trinocular microscope with robotic control of illumination intensity, mechanical stage, objectives, and coarse and fine focusing facilities and is equipped with a high-resolution camera." Some models handle batches, with "high-throughput scanners (handling up to 400 slides)", and "Scanning times can vary from 1 to 5 min for a small biopsy to 5-20 min for a surgical specimen." Scanning at 20x "magnification is considered suitable for routine surgical pathology and immunohistochemistry slides", while at 40x a single square millimeter of tissue "area results in a file size of 48 megabytes" (Journal of Digital Imaging).

The result is stored as tiles. DICOM describes a whole slide image as a "multi-frame visible light whole slide microscopy image divided into a set of tiles" (DICOM PS3.3). Whole slide images "can exceed several gigabytes, require full RGB color fidelity, and must be stored in multi-resolution pyramidal formats to enable efficient navigation" (Journal of Pathology Informatics).

What one scanned slide containsWhat it isWhy it matters
Tissue image pyramidThe tissue at full resolution plus smaller copies for zooming outThis is what the pathologist reads
Label imageA photograph of the slide labelConfirms the case and stain; it can show patient details
Macro imageA low-power picture of the whole slideShows where the tissue sits; it can also capture the label
MetadataCase accession number, specimen, stain and scan settingsLinks the image back to the lab system and the block
AnnotationsMarks and measurements added on screenRecord what the pathologist pointed out

In DICOM, "the label image and a macro image are stored as separate DICOM instances but linked by a common series identifier" (Journal of Pathology Informatics).

Can pathologists diagnose from whole slide images?

Yes, with validated systems. "The first whole-slide imaging (WSI) device was authorized for marketing in the US in 2017 through the de novo pathway" (FDA). That system could "scan and digitize conventional surgical pathology glass slides prepared from biopsied tissue at resolutions equivalent to 400 times magnification", and "The FDA evaluated data from a clinical study of approximately 2,000 surgical pathology cases using tissue from multiple parts of the body (anatomic sites)" (FDA). By 2026, "In the United States, at least 10 whole slide scanners have been cleared or approved by the Food and Drug Administration (FDA)" (Journal of Pathology Informatics).

Each system's labeling must say: "It is the responsibility of a qualified pathologist to employ appropriate procedures and safeguards to assure the validity of the interpretation of images obtained using this device." It must also tell pathologists to "examine the glass slides by conventional microscopy if there is doubt about the ability to accurately render an interpretation using this device alone" (21 CFR 864.3700).

Labs validate before going live. The College of American Pathologists notes that "The US Food and Drug Administration has approved select digital whole slide imaging (WSI) systems for primary diagnoses in surgical pathology", and its guideline "helps pathologists and laboratories confirm diagnostic accuracy and equivalence with light microscopy of WSI systems before they are actually used for diagnostic purposes"; the 2021 update "offers three strong recommendations and nine good practice statements" (CAP).

Remote sign-out has its own rule. CMS uses "enforcement discretion to permit pathologists and other laboratory personnel to review digital laboratory data, digital results and digital images" away from the lab under the primary site's certificate, and "A private residence may be a remote testing site." Cytology is the exception: "laboratories reviewing digital images of cytology slides at a remote location will need to obtain a separate CLIA certificate to continue reviewing cytology slides" (CMS QSO-23-15-CLIA).

What file formats do whole slide images use?

Mostly the scanner maker's own. As the field grew, "each vendor entering the market developed its own WSI file format", and "none of them are directly interoperable" (Journal of Pathology Informatics). That matters when a lab adds a second scanner, changes image systems or sends cases to another institution.

DICOM now covers pathology too. "Supplement 145, ratified in 2010, addressed these limitations by defining the Visible Light (VL) Whole Slide Microscopy Image Information Object Definition (IOD)." A DICOM slide can sit in the same kind of archive as radiology studies, since "Over the subsequent three decades, DICOM achieved near-universal adoption in radiology" (Journal of Pathology Informatics). When choosing a scanner or image management system, ask whether it writes DICOM natively or can export it. The PACS radiology guide explains how DICOM archives work.

FeatureRadiology studyWhole slide image
Typical sizeMegabytesCan exceed several gigabytes per slide
ColorMostly grayscaleFull color
ResolutionA single resolutionA multi-resolution pyramid of tiles
Standard formatDICOM almost everywhereVendor formats dominate; DICOM defined since 2010
Source of patient and case dataRadiology information systemLaboratory information system

The radiology column follows the same review: "Radiology images are typically measured in megabytes, rendered in grayscale, and stored at a single resolution" (Journal of Pathology Informatics).

How long must pathology slides and blocks be kept?

CLIA, the federal lab rule, sets the minimums: "The laboratory must retain its records and, as applicable, slides, blocks, and tissues as follows" (42 CFR 493.1105). The pathology periods are in the table. State law, accreditors and the lab's own policy can require longer.

Record or materialCLIA minimumRule text
Histopathology slides10 years from examination"Retain histopathology slides for at least 10 years from the date of examination."
Cytology slides5 years from examination"Retain cytology slide preparations for at least 5 years from the date of examination"
Paraffin blocks2 years from examination"Retain pathology specimen blocks for at least 2 years from the date of examination."
Tissue remnantsUntil diagnosis"Preserve remnants of tissue for pathology examination until a diagnosis is made on the specimen."
Pathology reports10 years from reporting"Pathology test reports for at least 10 years after the date of reporting."

Some institutions keep them much longer. The University of Missouri System's schedule for glass slides and blocks reads "Retention Period: 25 Years" (UM System). The CLIA rule names slides and blocks and does not say that a scan replaces them, so keep the glass for the full period after scanning. If a lab closes, it "must make provisions to ensure that all records and, as applicable, slides, blocks, and tissue are retained and available" for those periods (42 CFR 493.1105). For patient charts, see how long to keep patient records. This page is general information, not legal advice.

Digital pathology example: scanning back a slide archive (illustrative)

An illustrative plan for a fictional hospital pathology department that has gone digital for new cases and is deciding what to do with its glass archive. The slide counts and the 1.5 GB average per slide are assumptions for this page.

Archive sliceGlass slidesPlanStorage at 1.5 GB a slide
2024 to 202690,000Scan all; these cases are still activeAbout 135 TB
2019 to 2023140,000Scan cancer cases and second opinions only, about 30,000 slidesAbout 45 TB
2016 to 201870,000Keep the glass to meet the 10-year rule; scan on requestNone up front
Paraffin blocks120,000Keep; blocks are never scannedNone

Fictional example written for this page. The department keeps every slide for its full retention period whether or not it was scanned, and records the scan date and file location in the lab system.

Common mistakes in digital pathology

Most problems come from treating the scan as a replacement for the glass, or the scanner as a closed box.

  • Discarding glass slides after scanning, before the CLIA period ends.
  • Going live for diagnosis without validating the system against light microscopy, as the CAP guideline asks.
  • Scanning poor slides. "The WSI images would be only as good as the original glass slide" (Journal of Digital Imaging).
  • Storing images only in one vendor format with no DICOM export path.
  • Forgetting that label and macro images can show patient names and numbers.
  • Reviewing cytology digital images from home without a CLIA certificate for that location.
  • Saving scans without the accession number that links them to the case, block and report.

Are pathology slides and reports a data asset?

They can be, when scanned slides are paired with their reports. AI data buyers have asked Origin for imaging with reports: CT, MRI, X-ray, and pathology slides. The buyer's stated requirements are de-identification signed off by an independent third party under HIPAA's Expert Determination method (not by the seller); IRB approval, or patient consent that covers commercial licensing; and a clear chain of rights (who collected the data, who owns it, who can license it). These deals need that paperwork to get through.

What must come out first: label and macro images, accession and record numbers, names and exact dates in reports, and anything the lab holds for a referring hospital under contract. Glass, blocks and tissue never leave the lab. The guide to licensing pathology slides and reports covers ownership, consent and the first sample.

Origin is an independent data partner. It helps an owner work out what they hold, which of the three requirements they already meet and what is missing; it does not perform Expert Determination or IRB review. Your organization decides what is shared and signs any license itself, and a buyer may pay Origin when a deal closes.

Does your company hold records like these? See what your data is worth.

Common questions

What is the difference between digital pathology and whole slide imaging?

Whole slide imaging is the scanning step: a scanner turns one glass slide into a high-resolution, tiled image. Digital pathology is the wider practice built on those images, including viewing, sharing, storing, analyzing and diagnosing from them. A lab can use whole slide imaging for teaching or second opinions without making digital diagnosis its routine.

How big is a whole slide image file?

Often hundreds of megabytes to several gigabytes per slide. Size depends on the tissue area, the magnification and the compression. One review reports that scanning a single square millimeter at 40x gives about 48 megabytes, which is why most systems compress images and store them as multi-resolution pyramids of tiles.

Do labs have to keep glass slides after they are scanned?

Yes. CLIA sets retention periods for the slides themselves: at least 10 years for histopathology slides and 5 years for cytology slides from the date of examination. The rule does not say a scan replaces the glass, so labs keep it for the full period. FDA-required labeling also tells pathologists to check the glass when in doubt.

How long do labs keep paraffin blocks?

CLIA sets a minimum of 2 years from the date of examination for pathology specimen blocks, but some institutions keep them far longer. The University of Missouri System, for example, keeps glass slides and paraffin blocks for 25 years. State law and accreditors can also require longer periods.

Is whole slide imaging FDA approved for primary diagnosis?

Yes, for specific systems. The FDA authorized the first whole slide imaging system for reviewing surgical pathology slides in 2017 through the de novo pathway, and at least 10 scanners have since been cleared or approved in the US. Each is a Class II device, and labs still validate it against light microscopy before using it for diagnosis.

Can a pathologist review digital slides from home?

For most digital images, yes. CMS permits pathologists to review digital data, results and images remotely under the primary lab's CLIA certificate, and a private residence can be the remote site. Cytology is different: reviewing digital cytology slides remotely needs a separate CLIA certificate for that location, and reviewing physical slides away from the lab is not covered.

What is a histopathological slide?

A histopathological slide is a thin section of tissue from a biopsy or surgical specimen, mounted on glass and stained so a pathologist can examine it under a microscope. The routine stain is H&E, and special stains or immunostains are added when needed. In digital pathology the same slide is scanned into a whole slide image.

What does a digital pathology scanner do?

It works like a robotic microscope with a high-resolution camera. It loads glass slides, finds the tissue, focuses and captures it in tiles, then stitches the tiles into one whole slide image. High-throughput models hold hundreds of slides. Scan time runs from a minute or two for a small biopsy to many minutes for a large surgical specimen.

Sources and further reading

What is your company’s data worth?

AI companies pay $20K to $5M for company records. Six questions, no files.